FireSAFE 4X
- 4-Hour Fire-Rated
- 8 ft x 40 ft
- 57 Barrels
- 55 Gal Storage Drums
- 228 Square Feet storage
Compliant storage and rental solutions for Nitrocellulose, Collided ((C 6H 9(NO 2)O 5) n). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
Nitrocellulose is a highly flammable compound formed by nitrating cellulose through exposure to a mixture of nitric acid and sulfuric acid
Acute toxicity - Oral Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2A Reproductive toxicity Category 1A Specific target organ toxicity (single exposure) Category 3 Specific target organ toxicity (repeated exposure) Category 1
Dry Chemical fire suppression is recommended for Nitrocellulose, Collided
Guidance: Dry Chemical fire suppression is generally recommended for Nitrocellulose, collided ((C 6H 9(NO 2)O 5) n). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Suitable Extinguishing Media Dry chemical. Carbon dioxide (CO2). water spray. Alcohol resistant foam. Large Fire CAUTION: Use of water spray when fighting fire may be inefficient
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Nitrocellulose, collided should account for its listed hazards (Flammable Liquids Category 1), climate control needs, and segregation requirements. Incompatible materials Strong acids. Strong bases. Strong oxidizing agents
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: Boiling point: 95 degrees Farenhite ==============
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Nitrocellulose, collided in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable Liquids Category 1). Climate range guidance: Follow the temperature range listed on the manufacturer SDS.. Compatibility notes: Incompatible materials Strong acids. Strong bases. Strong oxidizing agents US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Nitrocellulose, collided is flagged as a flammable hazard in this database (Yes). Flash point: -47 °C / -52.6 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Nitrocellulose, collided is listed as: Flammable Liquids Category 1. Acute toxicity - Oral Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2A Reproductive toxicity Category 1A Specific target organ toxicity (single exposure) Category 3 Specific target organ toxicity (repeated exposure) Category 1
Dry Chemical fire suppression is generally recommended for Nitrocellulose, collided ((C 6H 9(NO 2)O 5) n). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Nitrocellulose, collided. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.